Product description
Foam glass plate is made of broken glass, foaming agent, modified additives and foaming accelerator, etc., through fine grinding and uniform mixing, and then through high temperature melting foaming, annealing and made of inorganic non-metallic glass materials.
Foam glass panels can be widely used for thermal insulation of external walls and roofs of civil buildings. Due to the characteristics of light weight, fireproof, waterproof, non-pollution, non-combustion, long life (the same long life as the building), and human requirements for living environment protection are getting higher and higher, foam glass is the ideal wall insulation material and roof insulation material for civil buildings.
The foam glass plate is both a cold retaining material and a thermal insulation material, which can adapt to the characteristics of deep cooling to higher temperature ranges. At the same time, its important value is not only that it will not deteriorate for a long time, but also plays a role in fire prevention and shock prevention. It is not only safe and reliable, but also durable when used in the harsh environment of low temperature and deep cold, underground engineering, flammable and explosive, wet and chemical erosion, and is known as "permanent insulation material that does not need to be replaced". Therefore, it is widely used in petroleum, chemical industry, underground engineering, shipbuilding, national defense military insulation and cold insulation and flue lining anti-corrosion engineering.
Products advantage
Focus on quality, rich in experience, quality after-sales service, support customization, fast delivery
Low thermal conductivity
Good performance, widely used in industrial civil building external wall insulation system
Sound absorption noise reduction
With closed cell structure, can provide a comfortable and quiet indoor environment
Stable performance
Physical and chemical properties are stable, not easy to crack, long use time
Thickening design
Thickening design, good insulation effect, uniform density, stable performance.
Product Parameters
Test Items |
Test Method |
Unit |
MY500 |
MY800 |
MY1000 |
MY1200 |
MY1400 |
MY1600 |
MY2400 |
|
Density (±10% Tolerance) |
ASTM C303 |
kg/m³ |
115 |
120 |
130 |
140 |
150 |
160 |
200 |
|
Thermal Conductivity Compressive Strength |
Ave.Value |
ASTM C177/C518 |
W/(m.K)(10℃) |
0.04 |
0.043 |
0.044 |
0.046 |
0.047 |
0.048 |
0.056 |
|
Highest Single Value |
|
W/(m.K)(10℃) |
0.042 |
0.044 |
0.046 |
0.048 |
0.049 |
0.05 |
0.058 |
|
Ave.Value |
ASTM C165 |
Mpa |
0.5 |
0.8 |
1 |
1.2 |
1.4 |
1.6 |
2.4 |
|
Lowest Single Value |
|
Mpa |
0.42 |
0.55 |
0.69 |
0.83 |
0.97 |
1.1 |
1..66 |
Bending Strength Average |
ASTM C203 |
Mpa |
≥0.283 |
≥0.310 |
≥0.351 |
≥0.386 |
≥0.434 |
≥0.476 |
≥0.627 |
|
Water Absorption |
ASTM C240 |
Vol% |
≤0.50 |
|||||||
Water Vapor Permeability |
ASTM E96 |
ng/(pa.m.s) |
≤0.007 |
|||||||
Coefficient of Linear Thermal Expansion |
ASTM E228 |
1/K |
9×10-6 |
|||||||
Service Temperature |
|
℃ |
-268~480 |
|||||||
Combustibility |
Non Combustible(Class A1) |
|||||||||
Dimensional Stability |
Excellent Stability |
|||||||||
Colour |
Black |