MYREAL Thermal Insulation Rubber Foam Pipe for HVAC Ductwork Transitions
Basic Properties
Trading Properties
| Product Name: | Closed Cell Rubber Foam Pipe For Duct Transitions | Application: | HVAC Ductwork Transitions |
|---|---|---|---|
| Inner Diameter: | 10-89 Mm | Wall Thickness: | 9-20 Mm |
| Nominal Density: | 68 Kg/m3 | Thermal Conductivity: | <=0.034 W/(m.K) At 0 C |
| Water Vapour Diffusion Resistance: | >=10,000 | Structure Option: | Round Or Slit Self-adhesive |
| Fire Rating: | B1 | Length Per Piece: | 2 M |
Where a round duct meets a rectangular trunk, where a flexible connector joins two duct sections, and where refrigerant or chilled water pipes cross a duct void, the insulation detail decides whether the system sweats or stays dry. This rubber foam pipe covers those transition points.
The tube cuts cleanly with a knife and holds a straight edge, so it can be shaped into short sleeves, collars and mitred segments that fit around duct connections and pipe penetrations. Easy cutting and installation matters on ductwork because the transitions are always made on site, after the duct is hung.
A closed cell structure means the sleeve needs no separate vapour barrier. That is the practical advantage over wrapped mineral products at duct connections, where a taped jacket is difficult to keep continuous around corners and brackets.
Effective condensation control follows from a thermal conductivity of 0.034 W/(m·K) and a vapour resistance above 10,000, which together keep the outer surface above dew point on cold air and chilled water connections. Tubes are supplied from 10 mm to 89 mm inner diameter in 2 m lengths with 9 mm to 20 mm wall.
| Parameter | Specification |
|---|---|
| Product | MYREAL Thermal Insulation Rubber Foam Pipe for HVAC Ductwork Transitions |
| Model | FR-13X19 |
| Material | NBR/PVC elastomeric rubber foam, closed cell |
| Colour | Black |
| Nominal Density | 68 kg/m³ (65–72 kg/m³) |
| Thermal Conductivity at 0 °C | ≤0.034 W/(m·K) |
| Service Temperature | -50 °C to +110 °C |
| Fire Performance | B1 (GB 8624) |
| Oxygen Index | ≥32 % |
| Water Vapour Diffusion Resistance | ≥10,000 |
| Water Absorption by Volume | ≤10 % |
| Cutting | Clean cut with a knife, no crumbling |
| Inner Diameter Range | 10–89 mm |
| Wall Thickness Range | 9–20 mm |
| Length per Piece | 2 m |
| Structure Option | Round or slit with self-adhesive lap |
| Application | HVAC ductwork transitions and duct connections |
| Packaging | Cartons / PE Bags |
| Minimum Order | 1 carton |
| Delivery Time | 15–20 days |
| Model | Inner Diameter (mm) | Wall Thickness (mm) | Length (m/piece) |
|---|---|---|---|
| FR-09X10 | 10 | 9 | 1.8 |
| FR-09X13 | 13 | 9 | 1.8 |
| FR-09X16 | 16 | 9 | 1.8 |
| FR-09X19 | 19 | 9 | 1.8 |
| FR-09X22 | 22 | 9 | 1.8 |
| FR-09X25 | 25 | 9 | 1.8 |
| FR-13X19 | 19 | 13 | 2 |
| FR-13X22 | 22 | 13 | 2 |
| FR-13X25 | 25 | 13 | 2 |
| FR-13X28 | 28 | 13 | 2 |
| FR-13X34 | 34 | 13 | 2 |
| FR-20X43 | 43 | 20 | 2 |
| FR-20X48 | 48 | 20 | 2 |
| FR-20X60 | 60 | 20 | 2 |
| FR-20X76 | 76 | 20 | 2 |
| FR-20X89 | 89 | 20 | 2 |
Model code format: FR-[wall thickness]X[inner diameter]. The 9 mm wall tube is supplied in 1.8 m pieces; all other walls in 2 m pieces. Special sizes and 40 mm wall tubes can be produced to order.
- Easy cutting and installation: the tube cuts with a knife and keeps a clean edge, so sleeves and collars can be made on site to fit duct transitions.
- Integrated vapour barrier: a closed cell structure supplies the vapour barrier directly, removing difficult taping work at corners, brackets and duct penetrations.
- Effective condensation control: keeps duct connection surfaces above dew point on cold air and chilled water services.
- Flexible fit: the tube bends around round duct tappings and flexible connectors without creasing, so airflow paths stay fully insulated.
- B1 fire performance: supports use in risers, plant rooms and ceiling voids in commercial buildings.
- Slit option available: supplied in slit form with a self-adhesive lap for insulating connections that are already installed and cannot be dismantled.
- Round duct to rectangular trunk transitions
- Flexible connector and vibration isolator sleeves
- Duct penetration and wall sleeve insulation
- Chilled water and refrigerant pipe crossings in duct voids
- Air handling unit spigot and plenum connections
Use the slit version. Cut the tube to the length of the transition, open it along the cut, wrap it around the duct or pipe and close the seam with the self-adhesive lap. Work from the bottom up so the lap overlaps in the direction of any condensation flow.
Yes. Clean the duct surface, then fit the tube over the spigot or connection and seal the ends. For mechanical protection on larger transitions, a foil faced finish can be added over the tube.
Use at least the same thickness as the pipe insulation on that line, normally 13 mm to 20 mm, and seal both ends so the vapour barrier is continuous through the duct wall.
Yes, provided the void stays dry and the material is not exposed to direct sunlight. The B1 rating supports use in ceiling voids and risers in commercial buildings.
Contact Person: Mrs. Betsy Ouyang
Tel: +86 177 4080 0950