logo

MYREAL Flexible Foam Rubber Tube Tight Bend Refrigeration Pipework Insulation

Basic Properties

Place of Origin:Shanghai, China
Brand Name:MYREAL
Certification:ISO 9001:2015, CE, RoHS, B1 / Class 0 Fire Rating
Model Number:FR-15X13

Trading Properties

Minimum Order Quantity:1 carton
Standard Packaging:Cartons / PE Bags
Delivery Time:15-20 days
Payment Terms:T/T
Supply Ability:Subject to order quantity and specifications
Specifications
Product Name: Flexible Closed Cell Anti-Condensation Foam Tube Application: Tight Bend Refrigeration Pipework
Inner Diameter: 6-28 Mm Wall Thickness: 9-15 Mm
Nominal Density: 62 Kg/m3 Thermal Conductivity: <=0.033 W/(m.K) At 0 C
Minimum Bend Radius: 2 X Outer Diameter Compression Set: <=15 % At 25 %
Fire Rating: B1 Length Per Piece: 1.8 M Or 2 M
Product Description
Product Overview

Refrigeration pipework rarely runs straight. Coil connections, capillary transitions, accumulator bends and the short offsets around a condensing unit all demand insulation that follows a tight radius without creasing or collapsing. That is the duty this flexible foam rubber tube was developed for.

The compound is soft enough to bend around a radius of twice the tube diameter without kinking, and it recovers its section afterwards, so the wall thickness stays even around the bend. Even thickness is what keeps the surface temperature above dew point on a suction line, and it is the detail that distinguishes a properly installed bend from a taped-up one.

Closed-cell moisture resistance protects performance once the system is running. Water vapour cannot pass through the cell walls, so the anti-condensation performance does not depend on a separate jacket, which on a tight bend is almost impossible to fit neatly.

Tubes are supplied from 6 mm to 42 mm inner diameter with 9 mm to 15 mm wall in 1.8 m or 2 m lengths. Pre-formed elbows in matching material are available for standard pipe sizes where the radius is tighter than the tube can follow.

Technical Specifications
Parameter Specification
ProductMYREAL Flexible Foam Rubber Tube Tight Bend Refrigeration Pipework Insulation
ModelFR-15X13
MaterialSoft NBR/PVC elastomeric rubber foam, closed cell
ColourBlack
Nominal Density62 kg/m³ (58–68 kg/m³)
Thermal Conductivity at 0 °C≤ 0.033 W/(m·K)
Service Temperature−50 °C to +105 °C
Minimum Bend Radius2 times the tube outer diameter without kinking
Fire PerformanceB1 (GB 8624)
Oxygen Index≥ 32 %
Water Vapour Diffusion Resistance≥ 8,000
Compression Set at 25 %≤ 15 %
Inner Diameter Range6–28 mm
Wall Thickness Range9–15 mm
Length per Piece1.8 m or 2 m
ApplicationTight bend refrigeration pipework and coil connections
AccessoryPre-formed elbows in matching material on request
PackagingCartons / PE Bags
Minimum Order1 carton
Delivery Time15–20 days
Standard Tight Bend Pipe Sizes
Model Inner Diameter (mm) Wall Thickness (mm) Length (m/piece)
FR-09X06691.8
FR-09X101091.8
FR-09X131391.8
FR-09X161691.8
FR-09X191991.8
FR-09X222291.8
FR-09X252591.8
FR-09X282891.8
FR-13X066132
FR-13X1010132
FR-13X1313132
FR-13X1616132
FR-13X1919132
FR-13X2222132
FR-13X2525132
FR-15X1010152
FR-15X1313152
FR-15X1919152
FR-15X2525152

Model code format: FR-[wall thickness]X[inner diameter]. The 9 mm wall tube is supplied in 1.8 m pieces; all other walls in 2 m pieces. Special sizes and 40 mm wall tubes can be produced to order.

Key Advantages
  • Excellent flexibility around a radius of twice the tube diameter avoids the kinks and thin spots that cause condensation at bends.
  • Closed-cell moisture resistance keeps the vapour barrier inside the material, even where a jacket cannot be fitted neatly.
  • Anti-condensation performance holds on coil connections and short offsets where the surface area is small and the dew point margin is tight.
  • Compression set under 15 % means the tube recovers after being squeezed through a tight gap during installation.
  • A soft 62 kg/m³ compound is easier to work around capillary tubes and small-diameter suction lines than a dense industrial grade.
  • Pre-formed elbows in matching material are available when the radius is tighter than the tube can follow.
Typical Applications
  • Condensing unit and evaporator coil connections
  • Accumulator, filter drier and capillary transitions
  • Short offsets and dog legs in refrigeration pipework
  • Display cabinet and cold room unit connections
  • Transport refrigeration and container unit piping
Frequently Asked Questions
Will the tube kink on a tight 90-degree bend?

The tube handles a radius of about twice its outer diameter without kinking. For tighter radii, use a pre-formed elbow in matching material, or cut the tube into short mitred segments and bond them with contact adhesive.

Does bending reduce the insulation performance?

Only if the wall thins on the outside of the bend. This compound resists that, which is why the density is held at 62 kg/m³ with a compression set under 15 %. Fit pre-formed elbows where the radius is extreme and performance stays as designed.

Can the tube be used on a suction line at −30 °C?

Yes, the service range covers it, and the closed-cell structure stays flexible at low temperature. Use 13 mm to 15 mm wall on the suction line and seal every joint with adhesive.

Are pre-formed elbows supplied separately?

Yes. We supply elbows, tees and end caps in the same material for standard pipe sizes, so the vapour barrier can be kept continuous around fittings.