MYREAL Closed Cell Elastomeric Foam Insulation Tube for District Chilled Water Pipes
Basic Properties
Trading Properties
| Product Name: | High Vapour Resistance Elastomeric Foam Insulation Tube | Application: | District Chilled Water Pipes |
|---|---|---|---|
| Inner Diameter: | 22-114 Mm | Wall Thickness: | 20-35 Mm |
| Nominal Density: | 70 Kg/m3 | Thermal Conductivity: | <=0.034 W/(m.K) At 0C |
| Water Vapour Diffusion Resistance: | >=10,000 | Water Absorption: | <=10 % By Volume |
| Fire Rating: | B1 / Class 0 | Length Per Piece: | 2 M |
Chilled water pipework is the hardest duty for any insulation: the pipe runs at 4 to 12 °C, the surrounding air carries moisture, and any weak point in the vapour barrier shows up as a damp patch, a drip or corrosion under the insulation. This closed cell elastomeric foam insulation tube is built for that duty.
High water vapour resistance is the property that carries the performance. The foam has a diffusion resistance factor above 7,000 and a measured permeability of at least 10,000, so vapour movement through the wall stays low even after years of cycling. Combined with a closed cell structure, this delivers anti-condensation performance without an extra jacket on indoor lines.
Energy saving thermal insulation comes from a thermal conductivity of 0.034 W/(m·K) at 0 °C that is stable over the service life. On a district cooling substation, that translates into a lower chilled water temperature rise between the plant and the furthest air handling unit, and less pump energy to compensate.
The tube is supplied from 6 mm to 114 mm inner diameter in 2 m pieces with walls from 20 mm to 35 mm, and covers elbows and fittings when cut into mitred segments. Self-adhesive lap tape and contact adhesive are supplied with the order so the vapour barrier can be closed on site.
| Parameter | Specification |
|---|---|
| Product | MYREAL Closed Cell Elastomeric Foam Insulation Tube for District Chilled Water Pipes |
| Model | FR-30X76 |
| Material | Elastomeric NBR/PVC closed cell foam |
| Colour | Black |
| Nominal Density | 70 kg/m³ (65–75 kg/m³) |
| Thermal Conductivity at 0 °C | ≤0.034 W/(m·K) |
| Thermal Conductivity at 20 °C | ≤0.036 W/(m·K) |
| Service Temperature | −50 °C to +110 °C |
| Fire Performance | B1 (GB 8624), Class 0 (BS 476 part 6 and 7) |
| Water Vapour Diffusion Resistance | ≥10,000, μ factor ≥7,000 |
| Water Absorption by Volume | ≤10 % |
| Anti-Condensation | Surface stays above dew point at specified wall thickness |
| Inner Diameter Range | 22–114 mm |
| Wall Thickness Range | 20–35 mm |
| Length per Piece | 2 m |
| Application | Chilled water and district cooling pipework |
| Thermal Stability | K value change under 5 % after 150 h at 105 °C |
| Packaging | Cartons / PE Bags |
| Minimum Order | 1 carton |
| Delivery Time | 15–20 days |
| Model | Inner Diameter (mm) | Wall Thickness (mm) | Length (m/piece) |
|---|---|---|---|
| FR-20X22 | 22 | 20 | 2 |
| FR-20X34 | 34 | 20 | 2 |
| FR-25X22 | 22 | 25 | 2 |
| FR-25X38 | 38 | 25 | 2 |
| FR-25X43 | 43 | 25 | 2 |
| FR-30X48 | 48 | 30 | 2 |
| FR-30X57 | 57 | 30 | 2 |
| FR-30X67 | 67 | 30 | 2 |
| FR-30X76 | 76 | 30 | 2 |
| FR-35X76 | 76 | 35 | 2 |
| FR-35X89 | 89 | 35 | 2 |
| FR-30X108 | 108 | 30 | 2 |
| FR-30X114 | 114 | 30 | 2 |
Model code format: FR-[wall thickness]X[inner diameter]. The 9 mm wall tube is supplied in 1.8 m pieces; all other walls in 2 m pieces. Special sizes and 40 mm wall tubes can be produced to order.
- High water vapour resistance with a diffusion factor above 7,000 keeps the closed cell core dry, which is what preserves insulation value on a 6 °C line.
- Anti-condensation performance is achieved at practical wall thicknesses: 20 mm to 25 mm covers most indoor chilled water sizes at standard design humidity.
- Energy saving thermal insulation with a stable 0.034 W/(m·K) reduces chilled water temperature rise between plant and terminal units.
- A closed cell structure resists water absorption below 10 % by volume, so a wet plant room does not degrade the material.
- B1 fire performance and low smoke suit mechanical rooms and occupied risers, including projects that specify Class 0.
- Tubes can be mitred and bonded on site for elbows, tees and valve bodies, keeping the vapour barrier continuous across fittings.
- Chilled water supply and return mains in district cooling networks
- Air handling unit and fan coil connections in commercial buildings
- Chiller plant room headers, pumps and valves
- Data centre cooling distribution pipework
- Condensate and low temperature process water lines
It depends on pipe temperature, room condition and pipe diameter. As a guide, 19 mm suits pipes up to 35 mm in conditioned space at 60 % relative humidity, and 25 mm is used for larger pipes or humid plant rooms. Send us the design conditions and we will return the required thickness.
On indoor lines in normal building conditions, no, provided all joints and ends are sealed with adhesive. Outdoors, in washdown areas or in very high humidity, we recommend a protective jacket over the tube.
Yes. The service range covers both, and the same tube can also be used on low temperature hot water if the system is later converted. Only the thickness selection changes.
We supply a product datasheet, batch test report, fire performance certificate and, on request, a condensation calculation for each pipe size and design condition in the project.
Contact Person: Mrs. Betsy Ouyang
Tel: +86 177 4080 0950