MYREAL Flexible Rubber Foam Insulation Pipe for Split VRV Air Conditioning
Basic Properties
Trading Properties
| Product Name: | Flexible Closed Cell Rubber Foam Insulation Pipe | Application: | Split And VRV Air Conditioning |
|---|---|---|---|
| Inner Diameter: | 6-38 Mm | Wall Thickness: | 9-25 Mm |
| Nominal Density: | 65 Kg/m3 | Thermal Conductivity: | <=0.033 W/(m.K) At 0 C |
| Elongation At Break: | >=150 % | Structure Option: | Round, Slit, Self-adhesive Lap |
| Fire Rating: | B1 | Length Per Piece: | 1.8 M Or 2 M |
This flexible rubber foam insulation pipe is made for split, multi-split and VRV air conditioning installations, where refrigerant lines leave the outdoor unit, cross a wall and then run inside a ceiling void to the indoor fan coil. The foam bends with the copper, so a line can be shaped on site without cutting the insulation into short straight pieces.
Tubes are supplied from 6 mm to 42 mm inner diameter with wall thickness from 9 mm to 25 mm. The elasticity of the NBR/PVC compound lets the same tube cover a nominal size range, which reduces the number of stock items an installer has to carry on a service van.
Because each cell is closed, the tube forms its own vapour barrier and does not need a separate wrap on indoor runs. That matters on air conditioning lines, where condensation dripping from a poorly sealed joint is the most common callback after a summer season.
The tube can be cut with a knife or pipe cutter, and slit versions open along one side so they can be fitted around an existing line without disconnecting the flare connections. Self-adhesive lap tape is available in matching widths so the seam closes to a continuous surface.
| Product | MYREAL Flexible Rubber Foam Insulation Pipe for Split VRV Air Conditioning |
|---|---|
| Model | FR-13X10 |
| Material | NBR/PVC elastomeric rubber foam |
| Colour | Black, with red and blue for hot and cold identification |
| Nominal Density | 65 kg/m³ (60–70 kg/m³) |
| Thermal Conductivity at 0 °C | ≤ 0.033 W/(m·K) |
| Service Temperature | −50 °C to +105 °C |
| Fire Performance | B1 (GB 8624) |
| Oxygen Index | ≥ 32 % |
| Water Vapour Diffusion Resistance | ≥ 8,000 |
| Elongation at Break | ≥ 150 % |
| Tensile Strength | ≥ 1.5 MPa |
| Inner Diameter Range | 6–38 mm |
| Wall Thickness Range | 9–25 mm |
| Length per Piece | 1.8 m or 2 m |
| Structure Option | Full round, slit, or slit with self-adhesive lap |
| Application | Split and VRV air conditioning refrigerant and condensate lines |
| Packaging | Cartons / PE bags |
| Minimum Order | 1 carton |
| Delivery Time | 15–20 days |
| Model | Inner Diameter (mm) | Wall Thickness (mm) | Length (m/piece) |
|---|---|---|---|
| FR-09X06 | 6 | 9 | 1.8 |
| FR-09X10 | 10 | 9 | 1.8 |
| FR-09X13 | 13 | 9 | 1.8 |
| FR-09X16 | 16 | 9 | 1.8 |
| FR-09X19 | 19 | 9 | 1.8 |
| FR-09X22 | 22 | 9 | 1.8 |
| FR-09X25 | 25 | 9 | 1.8 |
| FR-13X10 | 10 | 13 | 2 |
| FR-13X13 | 13 | 13 | 2 |
| FR-13X16 | 16 | 13 | 2 |
| FR-13X19 | 19 | 13 | 2 |
| FR-13X22 | 22 | 13 | 2 |
| FR-13X28 | 28 | 13 | 2 |
| FR-15X19 | 19 | 15 | 2 |
| FR-15X25 | 25 | 15 | 2 |
| FR-20X34 | 34 | 20 | 2 |
| FR-25X38 | 38 | 25 | 2 |
Model code format: FR-[wall thickness]X[inner diameter]. The 9 mm wall tube is supplied in 1.8 m pieces; all other walls in 2 m pieces. Special sizes and 40 mm wall tubes can be produced to order.
- Excellent flexibility means the tube follows the bends of refrigerant pipework without kinking, so the vapour barrier stays intact around every elbow.
- Easy cutting and installation with a knife or pipe cutter keeps the job moving, and slit versions fit around lines that cannot be disconnected.
- A closed-cell structure gives the pipe its own vapour barrier, which removes the need for a separate wrap on indoor runs.
- Elongation above 150 % allows the foam to be stretched over a slightly oversize joint and still recover to a tight fit.
- The low thermal conductivity of 0.033 W/(m·K) limits heat gain on suction lines and protects cooling capacity at the indoor unit.
- Red and blue colour options make hot gas and liquid line identification simple during commissioning and later maintenance.
- Split and multi-split air conditioner refrigerant lines
- VRV and VRF branch pipework and indoor unit connections
- Condensate drain lines where sweating is a concern
- Retrofit insulation of existing lines using slit tube
- Chilled water fan coil connections in hotel and office projects
The tube is slipped onto the copper before the flare is made, which is the normal method for new installations. For existing lines, use the slit version: open the tube along the cut, wrap it around the pipe and close the seam with the self-adhesive lap.
On indoor runs in conditioned space, 13 mm to 19 mm wall covers most sizes up to 28 mm diameter. For lines running through an unconditioned roof void or in high humidity, go to 25 mm wall to keep the surface above dew point.
The material resists ozone and UV for normal installation periods, but for long exposed runs we recommend wrapping the tube with a UV-resistant tape or aluminium foil jacket to protect the surface.
Pieces of the same size are packed in cartons or PE bags, and the minimum order is 1 carton for stock sizes. Each package is labelled with inner diameter, wall thickness and quantity so an installer can pick the right size without opening the pack. Delivery for standard items is 15 to 20 days.