MYREAL Thermal Insulation Rubber Foam Board for Industrial Applications
Basic Properties
Trading Properties
| Model Number: | FR-10100/ST | Thickness: | 10mm |
|---|---|---|---|
| Roll Width: | 1.0 M (1.5 M Optional) | Density: | 40 Kg/m3 |
| Thermal Conductivity: | ≤0.032-0.034 W/(m.K) | Fire Rating: | B1 |
| Oxygen Index: | ≥32 % | Service Temperature: | -50 C To +110 C |
| Water Vapor Permeability: | ≥10,000 G/m2-h | Compression Recovery: | ≥70 % |
| Noise Reduction: | 30-35 DB | Dimensional Stability: | ≤10 % |
| Application: | Industrial Applications | Product Name: | Thermal Insulation Rubber Foam Board |
The MYREAL thermal insulation rubber foam board is a flexible, closed-cell elastomeric sheet engineered for industrial applications such as HVAC duct and chilled water line insulation. Each board measures 1 m * 2 m at 10 mm thickness and achieves a thermal conductivity of ≤0.034 W/(m·K) at 40 kg/m³ density, so even a thin section maintains a stable surface temperature on both cold and hot services.
Every cell inside the rubber foam insulation board is closed and independent. Water vapour cannot pass through the cell walls, which means the board retains its thermal conductivity for the entire life of the duct run instead of becoming loaded with moisture. A water vapour permeability above 10,000 g/m²·h is the figure engineers compare when evaluating this board against open-cell products.
Boards are produced on a continuous extrusion and foaming line and then skived to 10 mm with a tolerance of ±1 mm. Incoming compound is tested for density and cell structure, and a retained sample from each batch is kept for two years, so every technical question can be traced back to its production record.
Myreal Energy Saving (Shanghai) Co., Ltd has supplied rubber foam insulation board to HVAC contractors in Europe, the Middle East and Southeast Asia since 2009. Every order ships with a datasheet, a batch test report and a condensation calculation for the actual project conditions.
| Parameter | Specification |
|---|---|
| Product | MYREAL Thermal Insulation Rubber Foam Board for Industrial Applications |
| Model | FR-10100/ST |
| Thickness | 10 mm |
| Nominal Density | 40 kg/m³ |
| Standard Width | 1.0 m (1.5 m optional) |
| Application | Industrial applications |
| Service Temperature | -50 °C to +110 °C |
| Density Range | 40–60 kg/m³ |
| Thermal Conductivity (0 °C) | ≤0.032–0.034 W/(m·K) |
| Fire Retardant | B1 |
| Oxygen Index | ≥32 % |
| Smoke Classification | ≤75 % |
| Water Absorption | ≤10 % |
| Water Vapor Permeability | ≥10,000 g/m²·h |
| Tear Strength | ≥3.5 N/cm |
| Dimensional Stability (105 °C, 7 days) | ≤10 % |
| Compression Recovery (50 %, 72 h) | ≥70 % |
| Noise Reduction | 30–35 dB |
| UV Resistance | No surface cracks in 460 h |
| Ozone Resistance | 202 MPa, 200 h, no cracks |
| Aging Resistance | 150 h, slight colour change, no cracks |
| Chemical Resistance | Stable to building material chemicals |
| Width (m) | Product Code | Thickness (mm) | Area (m²/roll) | Length (m) |
|---|---|---|---|---|
| 1 | FR-06100/ST | 6 | 30 | 30 |
| 1 | FR-10100/ST | 10 | 20 | 20 |
| 1 | FR-13100/ST | 13 | 15 | 15 |
| 1 | FR-15100/ST | 15 | 13 | 13 |
| 1 | FR-20100/ST | 20 | 10 | 10 |
| 1 | FR-25100/ST | 25 | 8 | 8 |
| 1 | FR-30100/ST | 30 | 6 | 6 |
| 1 | FR-35100/ST | 35 | 6 | 6 |
| 1.5 | FR-13150/ST | 13 | 22.5 | 15 |
| 1.5 | FR-15150/ST | 15 | 19.5 | 13 |
| 1.5 | FR-20150/ST | 20 | 15 | 10 |
| 1.5 | FR-25150/ST | 25 | 12 | 8 |
| 1.5 | FR-30150/ST | 30 | 9 | 6 |
| 1.5 | FR-35150/ST | 35 | 9 | 6 |
| 1.5 | FR-40150/ST | 40 | 7.5 | 5 |
| 1.5 | FR-50150/ST | 50 | 6 | 4 |
- Closed-cell structure gives the rubber foam insulation board a low thermal conductivity of ≤0.034 W/(m·K), which cuts heat gain on chilled ducts and heat loss on warm air ducts.
- The 10 mm thickness fits inside tight ceiling voids and equipment casings where thicker sections cannot be installed.
- A density of 40 kg/m³ stays consistent across the sheet, so insulation value does not vary from the first square metre to the last.
- Water vapour permeability above 10,000 g/m²·h protects the closed-cell core and limits corrosion under insulation.
- B1 (GB 8624) fire performance suits plant rooms, risers and public buildings.
- Boards are cut to 1 m * 2 m and packed in cartons or PE bags for direct site delivery.
- HVAC supply and return duct insulation
- Chilled water pipe and fitting wrap
- Air handling unit and fan coil casing lining
- Machine room and riser ductwork
- Industrial ventilation ductwork in food and pharma plants
For most comfort cooling ducts running at 6 to 12 °C in a conditioned space, 10 mm of this rubber foam insulation board is enough to keep the surface above dew point. For high-humidity rooms or outdoor runs we recommend 20 mm or 25 mm and supply a condensation calculation for the exact conditions.
Yes. The service temperature range of -50 °C to +110 °C covers warm air ducts, and the same closed-cell rubber foam insulation board is used on both supply and return lines without changing the fixing method.
Cut the board with a sharp knife, apply contact adhesive to both surfaces, wait for the adhesive to become tack-free, then press the board onto the duct. All joints should be butt-fit and sealed with the same adhesive or with a self-adhesive tape.
Every batch of rubber foam insulation board is sampled and tested for density, thermal conductivity and fire performance, and the batch test report travels with the shipping documents.
Contact Person: Mrs. Betsy Ouyang
Tel: +86 177 4080 0950