Basic Properties

Place of Origin:Shanghai, China
Brand Name:MYREAL
Certification:ISO 9001:2015, CE
Model Number:FR-20100/ST

Trading Properties

Minimum Order Quantity:1 carton
Standard Packaging:Cartons / PE Bags
Delivery Time:15-20 days
Payment Terms:T/T
Supply Ability:Subject to order quantity and specifications
Specifications
Model Number: FR-20100/ST Thickness: 20mm
Roll Width: 1.0 M (1.5 M Optional) Density: 45 Kg/m3
Thermal Conductivity: ≤0.032-0.034 W/(m.K) Fire Rating: B1
Oxygen Index: ≥32 % Service Temperature: -50 C To +110 C
Water Vapor Permeability: ≥10,000 G/m2-h Compression Recovery: ≥70 %
Noise Reduction: 30-35 DB Dimensional Stability: ≤10 %
Application: Air Conditioning Systems Product Name: Closed Cell Rubber Foam Sheet
Product Description
Product Overview

The MYREAL closed cell rubber foam sheet is engineered for air conditioning systems with outdoor and high humidity ductwork, where a plain elastomeric surface would collect water and degrade in sunlight. The 20mm foil faced sheet is supplied at 1 m x 2 m, 45 kg/m³, with thermal conductivity of ≤0.034 W/(m·K).

The reinforced aluminium foil facing performs two functions on this rubber foam insulation sheet. It reflects radiant heat and blocks water vapour at the surface, while protecting the elastomeric core from UV and weather. This combination makes the sheet suitable for rooftop ducts, outdoor chiller lines, and laundry or pool hall ventilation.

Sheets are produced on a continuous extrusion and foaming line, skived to 20mm within ±1 mm, then laminated with reinforced foil. Incoming compound is tested for density and cell structure, and a retained sample from each batch is kept for two years.

Myreal Energy Saving (Shanghai) Co., Ltd has supplied foil faced rubber foam insulation sheet to contractors in Europe, the Middle East, and Southeast Asia since 2009, including rooftop plant, coastal installations, and high humidity process buildings.

Technical Specifications
Parameter Specification
ProductMYREAL Closed Cell Rubber Foam Sheet for Air Conditioning Systems
ModelFR-20100/ST
Thickness20mm
Nominal Density45 kg/m³
Standard Width1.0 m (1.5 m optional)
ApplicationAir conditioning systems
Service Temperature-50 °C to +110 °C
Density Range40–60 kg/m³
Thermal Conductivity (0 °C)≤0.032–0.034 W/(m·K)
Fire RetardantB1
Oxygen Index≥32 %
Smoke Classification≤75 %
Water Absorption≤10 %
Water Vapor Permeability≥10,000 g/m²·h
Tear Strength≥3.5 N/cm
Dimensional Stability (105 °C, 7 days)≤10 %
Compression Recovery (50 %, 72 h)≥70 %
Noise Reduction30–35 dB
UV ResistanceNo surface cracks in 460 h
Ozone Resistance202 MPa, 200 h, no cracks
Aging Resistance150 h, slight colour change, no cracks
Chemical ResistanceStable to building material chemicals
Standard Roll Sizes
Width (m) Product Code Thickness (mm) Area (m²/roll) Length (m)
1FR-06100/ST63030
1FR-10100/ST102020
1FR-13100/ST131515
1FR-15100/ST151313
1FR-20100/ST201010
1FR-25100/ST2588
1FR-30100/ST3066
1FR-35100/ST3566
1.5FR-13150/ST1322.515
1.5FR-15150/ST1519.513
1.5FR-20150/ST201510
1.5FR-25150/ST25128
1.5FR-30150/ST3096
1.5FR-35150/ST3596
1.5FR-40150/ST407.55
1.5FR-50150/ST5064
Key Advantages
  • Reinforced foil facing gives the anti-condensation rubber foam insulation sheet a reflective surface and a UV-resistant skin.
  • The foil layer blocks water vapour at the surface, keeping the closed cell core dry in high humidity service.
  • 20mm thickness holds the duct surface above dew point on chilled and cold air systems.
  • Thermal conductivity of ≤0.034 W/(m·K) keeps heat gain low on long outdoor duct runs.
  • B1 (GB 8624) fire performance allows use on occupied building facades and rooftops.
  • The foil faced rubber foam insulation sheet is cut to 1 m x 2 m and packed in cartons or PE bags, and standard rolls of 1.0 m and 1.5 m width cover most rooftop and plant room layouts.
Typical Applications
  • Rooftop and outdoor duct insulation
  • High humidity process buildings and pool halls
  • Chiller and condenser water pipe wrap outdoors
  • Laundry and kitchen extract ductwork
  • Coastal installations requiring UV protection
Frequently Asked Questions
Why does the foil facing help against condensation?

The reinforced aluminium foil acts as a continuous vapour barrier on the outside of the anti-condensation rubber foam insulation sheet. It also reflects radiant heat, so the surface stays closer to ambient temperature and the risk of surface condensation drops.

Can the foil faced sheet be used without extra weather protection?

For most rooftop and facade ductwork the foil facing is sufficient. In coastal or heavily polluted environments we recommend sealing all joints with foil tape and adding a metal jacket on exposed vertical runs.

How are foil faced joints sealed?

Butt fit the sheets, bond with contact adhesive, and cover every joint with reinforced foil tape. The vapour barrier is only as good as its joints, so tape selection matters as much as the sheet itself.

Is the foil faced version available in other thicknesses?

Yes. The same rubber foam insulation sheet is produced with foil facing in 6mm, 10mm, 13mm, 20mm, 25mm, and 32mm, and the foil can be plain or reinforced.

Contact Details
Myreal Energy Saving (Shanghai) Co., Ltd.

Contact Person: Mrs. Betsy Ouyang

Tel: +86 177 4080 0950

Send your inquiry directly to us
(0/3000)