MYREAL Flexible Elastomeric Foam Insulation Board for Industrial Equipment
Basic Properties
Trading Properties
| Model Number: | FR-50150/ST | Thickness: | 50mm |
|---|---|---|---|
| Roll Width: | 1.5 M | Density: | 60 Kg/m3 |
| Thermal Conductivity: | ≤0.032-0.034 W/(m.K) | Fire Rating: | B1 |
| Oxygen Index: | ≥32 % | Service Temperature: | -50 C To +110 C |
| Water Vapor Permeability: | ≥10,000 G/m2-h | Compression Recovery: | ≥70 % |
| Noise Reduction: | 30-35 DB | Dimensional Stability: | ≤10 % |
| Application: | Industrial Equipment | Product Name: | Flexible Elastomeric Foam Insulation Board |
The MYREAL flexible elastomeric foam insulation board is engineered for industrial equipment insulation where a long service life is a core specification. Boards are supplied at 1 m × 2 m in 50 mm thickness at 60 kg/m³, with thermal conductivity of ≤0.034 W/(m·K) at 0 °C.
Service life is determined by density, cell structure, and dimensional stability working together. The NBR rubber foam insulation board is produced at 60 kg/m³ so the cell walls resist compression and moisture cycling, and dimensional stability of ±10% after ageing means the installed thickness stays within the design envelope for the life of the plant.
The rubber foam insulation board is skived to 50 mm within ±1 mm on the same continuous extrusion and foaming line used for thinner sections, and a retained sample from each batch is kept for two years. Thermal conductivity is measured on the finished board, not on the compound.
Myreal Energy Saving (Shanghai) Co., Ltd has supplied NBR rubber foam insulation board to industrial contractors in Europe, the Middle East, and Southeast Asia since 2009. Projects in petrochemical, food processing, and district cooling plants have run on this board for more than two decades of combined service.
| Parameter | Specification |
|---|---|
| Product | MYREAL Flexible Elastomeric Foam Insulation Board for Industrial Equipment |
| Model | FR-50150/ST |
| Thickness | 50 mm |
| Nominal Density | 60 kg/m³ |
| Standard Width | 1.5 m |
| Application | Industrial equipment |
| Service Temperature | -50 °C to +110 °C |
| Density Range | 40–60 kg/m³ |
| Thermal Conductivity (0 °C) | ≤0.032–0.034 W/(m·K) |
| Fire Retardant | B1 |
| Oxygen Index | ≥32% |
| Smoke Classification | ≤75% |
| Water Absorption | ≤10% |
| Water Vapor Permeability | ≥10,000 g/m²·h |
| Tear Strength | ≥3.5 N/cm |
| Dimensional Stability (105 °C, 7 days) | ≤10% |
| Compression Recovery (50%, 72 h) | ≥70% |
| Noise Reduction | 30–35 dB |
| UV Resistance | No surface cracks in 460 h |
| Ozone Resistance | 202 MPa, 200 h, no cracks |
| Aging Resistance | 150 h, slight colour change, no cracks |
| Chemical Resistance | Stable to building material chemicals |
| Width (m) | Product Code | Thickness (mm) | Area (m²/roll) | Length (m) |
|---|---|---|---|---|
| 1 | FR-06100/ST | 6 | 30 | 30 |
| 1 | FR-10100/ST | 10 | 20 | 20 |
| 1 | FR-13100/ST | 13 | 15 | 15 |
| 1 | FR-15100/ST | 15 | 13 | 13 |
| 1 | FR-20100/ST | 20 | 10 | 10 |
| 1 | FR-25100/ST | 25 | 8 | 8 |
| 1 | FR-30100/ST | 30 | 6 | 6 |
| 1 | FR-35100/ST | 35 | 6 | 6 |
| 1.5 | FR-13150/ST | 13 | 22.5 | 15 |
| 1.5 | FR-15150/ST | 15 | 19.5 | 13 |
| 1.5 | FR-20150/ST | 20 | 15 | 10 |
| 1.5 | FR-25150/ST | 25 | 12 | 8 |
| 1.5 | FR-30150/ST | 30 | 9 | 6 |
| 1.5 | FR-35150/ST | 35 | 9 | 6 |
| 1.5 | FR-40150/ST | 40 | 7.5 | 5 |
| 1.5 | FR-50150/ST | 50 | 6 | 4 |
- Density of 60 kg/m³ gives the rubber foam insulation board the compression resistance needed for a 25-year service life.
- 50 mm thickness delivers a deep thermal break on large industrial ducts and equipment.
- Dimensional stability within ±10% after ageing keeps the installed thickness on specification.
- NBR closed-cell structure with vapor permeability above 10,000 g/m²·h resists moisture cycling and corrosion under insulation.
- B1 (GB 8624) fire performance suits plant rooms and process buildings.
- Batch test reports and retained samples make the long-term performance claim traceable.
- Industrial HVAC and process ductwork
- District cooling and chiller plant pipework
- Petrochemical and food processing plant insulation
- Large air handling unit and plenum lining
- Equipment casings requiring long maintenance intervals
The claim is based on density of 60 kg/m³, closed-cell structure, dimensional stability within ±10% after ageing, and continuous service temperature within -50 °C to +110 °C. Retained samples from each batch let us review performance against production records.
50 mm is used where the temperature difference is large, where the duct is outdoors, or where the specification targets a specific surface temperature. The rubber foam insulation board thickness is chosen from the project thermal calculation.
The rubber foam insulation board remains flexible and is cut with a knife. On large flat duct panels, 50 mm sections install quickly; on small fittings, we recommend a thinner sheet to keep the vapour seal continuous.
Yes, the service range is -50 °C to +110 °C. For sub-zero process lines, the board is often combined with a vapour barrier jacket, and we provide the condensation and ice formation check for the duty.