MYREAL Rubber Foam Insulation Sheet for HVAC Thermal Insulation
Basic Properties
Trading Properties
| Model Number: | FR-40150/ST | Thickness: | 40mm |
|---|---|---|---|
| Roll Width: | 1.5 M | Density: | 60 Kg/m3 |
| Thermal Conductivity: | ≤0.032-0.034 W/(m.K) | Fire Rating: | B1 |
| Oxygen Index: | ≥32 % | Service Temperature: | -50 C To +110 C |
| Water Vapor Permeability: | ≥10,000 G/m2-h | Compression Recovery: | ≥70 % |
| Noise Reduction: | 30-35 DB | Dimensional Stability: | ≤10 % |
| Application: | HVAC Thermal Insulation | Product Name: | HVAC Thermal Insulation Rubber Foam Insulation Sheet |
The MYREAL rubber foam insulation sheet is engineered for HVAC thermal insulation, including roof and duct energy retrofit work where a measurable reduction in heat loss is the target. Sheets are supplied at 1 m × 2 m in 40 mm thickness at 60 kg/m³, with thermal conductivity of ≤0.034 W/(m·K).
Energy savings on an existing duct run depend on three factors: low thermal conductivity, a thickness that matches the temperature difference, and a vapour barrier that remains intact for years. This rubber foam insulation sheet delivers ≤0.034 W/(m·K) at 60 kg/m³, and field data from retrofit projects shows up to 30% reduction in heat loss compared with uninsulated or degraded ductwork.
Sheets are produced on a continuous extrusion and foaming line and skived to 40 mm within ±1 mm, with dimensional stability of ±10% after ageing. A retained sample from each batch is kept for two years, and the service life under specified conditions is 25 years.
Myreal Energy Saving (Shanghai) Co., Ltd has supplied energy-saving rubber foam insulation sheet to contractors in Europe, the Middle East and Southeast Asia since 2009. The retrofit guidance issued with each order is based on those building and industrial projects.
| Parameter | Specification |
|---|---|
| Product | MYREAL Rubber Foam Insulation Sheet for HVAC Thermal Insulation |
| Model | FR-40150/ST |
| Thickness | 40 mm |
| Nominal Density | 60 kg/m³ |
| Standard Width | 1.5 m |
| Application | HVAC thermal insulation |
| Service Temperature | -50 °C to +110 °C |
| Density Range | 40–60 kg/m³ |
| Thermal Conductivity (0 °C) | ≤0.032–0.034 W/(m·K) |
| Fire Retardant | B1 |
| Oxygen Index | ≥32% |
| Smoke Classification | ≤75% |
| Water Absorption | ≤10% |
| Water Vapor Permeability | ≥10,000 g/m²·h |
| Tear Strength | ≥3.5 N/cm |
| Dimensional Stability (105 °C, 7 days) | ≤10% |
| Compression Recovery (50%, 72 h) | ≥70% |
| Noise Reduction | 30–35 dB |
| UV Resistance | No surface cracks in 460 h |
| Ozone Resistance | 202 MPa, 200 h, no cracks |
| Aging Resistance | 150 h, slight colour change, no cracks |
| Chemical Resistance | Stable to building material chemicals |
| Width (m) | Product Code | Thickness (mm) | Area (m²/roll) | Length (m) |
|---|---|---|---|---|
| 1 | FR-06100/ST | 6 | 30 | 30 |
| 1 | FR-10100/ST | 10 | 20 | 20 |
| 1 | FR-13100/ST | 13 | 15 | 15 |
| 1 | FR-15100/ST | 15 | 13 | 13 |
| 1 | FR-20100/ST | 20 | 10 | 10 |
| 1 | FR-25100/ST | 25 | 8 | 8 |
| 1 | FR-30100/ST | 30 | 6 | 6 |
| 1 | FR-35100/ST | 35 | 6 | 6 |
| 1.5 | FR-13150/ST | 13 | 22.5 | 15 |
| 1.5 | FR-15150/ST | 15 | 19.5 | 13 |
| 1.5 | FR-20150/ST | 20 | 15 | 10 |
| 1.5 | FR-25150/ST | 25 | 12 | 8 |
| 1.5 | FR-30150/ST | 30 | 9 | 6 |
| 1.5 | FR-35150/ST | 35 | 9 | 6 |
| 1.5 | FR-40150/ST | 40 | 7.5 | 5 |
| 1.5 | FR-50150/ST | 50 | 6 | 4 |
- 40 mm of rubber foam insulation sheet delivers a deep thermal break for roof and duct retrofit work.
- Thermal conductivity of ≤0.034 W/(m·K) keeps heat loss low across the full service temperature range.
- Field results show up to 30% heat loss reduction against uninsulated or degraded ductwork.
- Density of 60 kg/m³ and dimensional stability within ±10% support a 25-year service life.
- Closed-cell structure with a vapor permeability above 10,000 g/m²·h keeps the insulation dry and effective.
- B1 (GB 8624) fire performance suits plant rooms, roofs and occupied buildings.
- Roof and duct energy retrofit projects
- Large air handling unit and plenum insulation
- Chilled and hot water pipe insulation in plants
- Industrial ventilation energy upgrade
- Building services insulation for energy audits
In duct and roof retrofit work, projects using the 40 mm energy-saving rubber foam insulation sheet report up to 30% reduction in heat loss compared with uninsulated or degraded ductwork. The exact figure depends on the temperature difference, run length and condition of the existing system.
40 mm is specified where the temperature difference is large, where the duct runs outdoors, or where the energy target requires a specific surface temperature. The rubber foam insulation sheet thickness should come from the project thermal calculation.
Under specified conditions the service life is 25 years. Density of 60 kg/m³, dimensional stability within ±10% after ageing and a closed-cell structure are what support that figure.
In most retrofit cases the old insulation is removed first so the vapour barrier can be rebuilt. Where the existing layer is dry and sound, the new rubber foam insulation sheet can be installed over it after the surface is cleaned and levelled.