logo

MYREAL Rubber Foam Insulation Sheet for HVAC Thermal Insulation

Basic Properties

Place of Origin:Shanghai, China
Brand Name:MYREAL
Certification:ISO 9001:2015, CE
Model Number:FR-40150/ST

Trading Properties

Minimum Order Quantity:1 carton
Standard Packaging:Cartons / PE Bags
Delivery Time:15-20 days
Payment Terms:T/T
Supply Ability:Subject to order quantity and specifications
Specifications
Model Number: FR-40150/ST Thickness: 40mm
Roll Width: 1.5 M Density: 60 Kg/m3
Thermal Conductivity: ≤0.032-0.034 W/(m.K) Fire Rating: B1
Oxygen Index: ≥32 % Service Temperature: -50 C To +110 C
Water Vapor Permeability: ≥10,000 G/m2-h Compression Recovery: ≥70 %
Noise Reduction: 30-35 DB Dimensional Stability: ≤10 %
Application: HVAC Thermal Insulation Product Name: HVAC Thermal Insulation Rubber Foam Insulation Sheet
Product Description
Product Overview

The MYREAL rubber foam insulation sheet is engineered for HVAC thermal insulation, including roof and duct energy retrofit work where a measurable reduction in heat loss is the target. Sheets are supplied at 1 m × 2 m in 40 mm thickness at 60 kg/m³, with thermal conductivity of ≤0.034 W/(m·K).

Energy savings on an existing duct run depend on three factors: low thermal conductivity, a thickness that matches the temperature difference, and a vapour barrier that remains intact for years. This rubber foam insulation sheet delivers ≤0.034 W/(m·K) at 60 kg/m³, and field data from retrofit projects shows up to 30% reduction in heat loss compared with uninsulated or degraded ductwork.

Sheets are produced on a continuous extrusion and foaming line and skived to 40 mm within ±1 mm, with dimensional stability of ±10% after ageing. A retained sample from each batch is kept for two years, and the service life under specified conditions is 25 years.

Myreal Energy Saving (Shanghai) Co., Ltd has supplied energy-saving rubber foam insulation sheet to contractors in Europe, the Middle East and Southeast Asia since 2009. The retrofit guidance issued with each order is based on those building and industrial projects.

Technical Specifications
ParameterSpecification
ProductMYREAL Rubber Foam Insulation Sheet for HVAC Thermal Insulation
ModelFR-40150/ST
Thickness40 mm
Nominal Density60 kg/m³
Standard Width1.5 m
ApplicationHVAC thermal insulation
Service Temperature-50 °C to +110 °C
Density Range40–60 kg/m³
Thermal Conductivity (0 °C)≤0.032–0.034 W/(m·K)
Fire RetardantB1
Oxygen Index≥32%
Smoke Classification≤75%
Water Absorption≤10%
Water Vapor Permeability≥10,000 g/m²·h
Tear Strength≥3.5 N/cm
Dimensional Stability (105 °C, 7 days)≤10%
Compression Recovery (50%, 72 h)≥70%
Noise Reduction30–35 dB
UV ResistanceNo surface cracks in 460 h
Ozone Resistance202 MPa, 200 h, no cracks
Aging Resistance150 h, slight colour change, no cracks
Chemical ResistanceStable to building material chemicals
Standard Roll Sizes
Width (m)Product CodeThickness (mm)Area (m²/roll)Length (m)
1FR-06100/ST63030
1FR-10100/ST102020
1FR-13100/ST131515
1FR-15100/ST151313
1FR-20100/ST201010
1FR-25100/ST2588
1FR-30100/ST3066
1FR-35100/ST3566
1.5FR-13150/ST1322.515
1.5FR-15150/ST1519.513
1.5FR-20150/ST201510
1.5FR-25150/ST25128
1.5FR-30150/ST3096
1.5FR-35150/ST3596
1.5FR-40150/ST407.55
1.5FR-50150/ST5064
Key Advantages
  • 40 mm of rubber foam insulation sheet delivers a deep thermal break for roof and duct retrofit work.
  • Thermal conductivity of ≤0.034 W/(m·K) keeps heat loss low across the full service temperature range.
  • Field results show up to 30% heat loss reduction against uninsulated or degraded ductwork.
  • Density of 60 kg/m³ and dimensional stability within ±10% support a 25-year service life.
  • Closed-cell structure with a vapor permeability above 10,000 g/m²·h keeps the insulation dry and effective.
  • B1 (GB 8624) fire performance suits plant rooms, roofs and occupied buildings.
Typical Applications
  • Roof and duct energy retrofit projects
  • Large air handling unit and plenum insulation
  • Chilled and hot water pipe insulation in plants
  • Industrial ventilation energy upgrade
  • Building services insulation for energy audits
Frequently Asked Questions
How much energy can the sheet save in a retrofit?

In duct and roof retrofit work, projects using the 40 mm energy-saving rubber foam insulation sheet report up to 30% reduction in heat loss compared with uninsulated or degraded ductwork. The exact figure depends on the temperature difference, run length and condition of the existing system.

Why choose 40 mm rather than 25 mm?

40 mm is specified where the temperature difference is large, where the duct runs outdoors, or where the energy target requires a specific surface temperature. The rubber foam insulation sheet thickness should come from the project thermal calculation.

What is the expected service life?

Under specified conditions the service life is 25 years. Density of 60 kg/m³, dimensional stability within ±10% after ageing and a closed-cell structure are what support that figure.

Can the sheet be installed over existing insulation?

In most retrofit cases the old insulation is removed first so the vapour barrier can be rebuilt. Where the existing layer is dry and sound, the new rubber foam insulation sheet can be installed over it after the surface is cleaned and levelled.

Contact Details
Myreal Energy Saving (Shanghai) Co., Ltd.

Contact Person: Mrs. Betsy Ouyang

Tel: +86 177 4080 0950

Send your inquiry directly to us
(0/3000)