Specifications
Model Number: FR-20100/ST Thickness: 20mm
Roll Width: 1.0 M (1.5 M Optional) Density: 45 Kg/m3
Thermal Conductivity: ≤0.032-0.034 W/(m.K) Fire Rating: B1
Oxygen Index: ≥32 % Service Temperature: -50 C To +110 C
Water Vapor Permeability: ≥10,000 G/m2-h Compression Recovery: ≥70 %
Noise Reduction: 30-35 DB Dimensional Stability: ≤10 %
Application: Building Applications Product Name: Closed Cell Elastomeric Insulation Sheet
Product Description
Product Overview

The MYREAL closed cell elastomeric insulation sheet is supplied for building applications such as cold duct and chilled water condensation control. Each 20mm sheet measures 1 m x 2 m at 45 kg/m³ and delivers ≤0.034 W/(m·K) thermal conductivity, so it holds a dry surface on low temperature services even in humid plant rooms.

Condensation, not heat gain, is the usual reason an insulation system fails on chilled service. The elastomeric foam insulation sheet resists moisture penetration and capillary wicking, which keeps water out of the insulation core and protects the duct or pipe substrate from corrosion under insulation. A water vapor permeability above 10,000 g/m²·h is the measured basis for that performance.

Each sheet is produced on a continuous extrusion and foaming line, then skived to 20mm within ±1 mm. Incoming compound is checked for density and cell structure, and a retained sample from every batch is archived for two years so that any field question can be answered from production records.

Myreal Energy Saving (Shanghai) Co., Ltd has delivered elastomeric foam insulation sheet to building services contractors in Europe, the Middle East and Southeast Asia since 2009, and the joint details and calculation methods issued today come directly from that project experience.

Technical Specifications
ParameterSpecification
ProductMYREAL Closed Cell Elastomeric Insulation Sheet for Building Applications
ModelFR-20100/ST
Thickness20mm
Nominal Density45 kg/m³
Standard Width1.0 m (1.5 m optional)
ApplicationBuilding applications
Service Temperature-50 °C to +110 °C
Density Range40–60 kg/m³
Thermal Conductivity (0 °C)≤0.032–0.034 W/(m·K)
Fire RetardantB1
Oxygen Index≥32 %
Smoke Classification≤75 %
Water Absorption≤10 %
Water Vapor Permeability≥10,000 g/m²·h
Tear Strength≥3.5 N/cm
Dimensional Stability (105 °C, 7 days)≤10 %
Compression Recovery (50 %, 72 h)≥70 %
Noise Reduction30–35 dB
UV ResistanceNo surface cracks in 460 h
Ozone Resistance202 MPa, 200 h, no cracks
Aging Resistance150 h, slight colour change, no cracks
Chemical ResistanceStable to building material chemicals
Standard Roll Sizes
Width (m)Product CodeThickness (mm)Area (m²/roll)Length (m)
1FR-06100/ST63030
1FR-10100/ST102020
1FR-13100/ST131515
1FR-15100/ST151313
1FR-20100/ST201010
1FR-25100/ST2588
1FR-30100/ST3066
1FR-35100/ST3566
1.5FR-13150/ST1322.515
1.5FR-15150/ST1519.513
1.5FR-20150/ST201510
1.5FR-25150/ST25128
1.5FR-30150/ST3096
1.5FR-35150/ST3596
1.5FR-40150/ST407.55
1.5FR-50150/ST5064
Key Advantages
  • Moisture resistant closed cell structure with a vapor permeability above 10,000 g/m²·h keeps condensation out of the elastomeric foam insulation sheet.
  • Water absorption ≤10 % by volume after 28 days means the sheet does not gain weight or lose insulation value in wet service.
  • 20mm thickness gives a surface temperature above dew point on chilled water and cold air ducts in most climate zones.
  • Density of 45 kg/m³ is stable across the panel, so thermal performance is repeatable from sheet to sheet.
  • B1 (GB 8624) fire performance allows use in occupied buildings and public areas.
  • The elastomeric foam insulation sheet is cut to 1 m x 2 m and packed in cartons or PE bags for direct delivery to site.
Typical Applications
  • Cold air duct insulation in humid climates
  • Chilled water and brine pipe insulation
  • Condensation control on air handling units
  • Cold storage room and refrigeration pipework
  • Building services insulation in hospitals, malls and hotels
Frequently Asked Questions
Why choose a moisture resistant elastomeric foam insulation sheet instead of open cell foam?

Open cell foam absorbs water vapour, and once the cell walls are wet the insulation value is lost. The closed cell elastomeric foam insulation sheet blocks vapour at the surface, keeps water absorption ≤10 % by volume and protects the pipe from corrosion under insulation.

Is 20mm enough for chilled water pipes in a humid climate?

For pipes running at 6 to 7 °C in a plant room at 32 °C and 80 % relative humidity, 20mm is normally sufficient when all joints are sealed. We run a condensation check for the project conditions and advise 25mm or 32mm where the margin is tight.

Can the sheet be painted or coated after installation?

The sheet can be left with its smooth closed cell skin, or finished with a water based coating for UV protection on outdoor runs. Solvent based paints should be tested on an offcut first.

What is the recommended installation method?

Cut the elastomeric foam insulation sheet to size, apply contact adhesive to the duct and to the sheet, allow both surfaces to become tack free and press firmly. Seal butt joints with adhesive or self adhesive tape.