MYREAL Flexible Rubber Foam Board for Refrigeration Equipment Insulation
Basic Properties
Trading Properties
| Model Number: | FR-25100/ST | Thickness: | 25mm |
|---|---|---|---|
| Roll Width: | 1.0 M (1.5 M Optional) | Density: | 50 Kg/m3 |
| Thermal Conductivity: | ≤0.032-0.034 W/(m.K) | Fire Rating: | B1 |
| Oxygen Index: | ≥32 % | Service Temperature: | -50 C To +110 C |
| Water Vapor Permeability: | ≥10,000 G/m2-h | Compression Recovery: | ≥70 % |
| Noise Reduction: | 30-35 DB | Dimensional Stability: | ≤10 % |
| Application: | Refrigeration Equipment Insulation | Product Name: | Flexible Rubber Foam Board |
The MYREAL flexible rubber foam board is produced for refrigeration equipment insulation, including plant room ductwork and cold room panel lining. Panels are supplied at 1 m × 2 m in 25 mm thickness at 50 kg/m³, with thermal conductivity of ≤0.034 W/(m·K).
Fire performance is the first question on most public building specifications, so this rubber foam insulation board is produced to B1 (GB 8624), and every shipment carries the matching test report. Low smoke development and self-extinguishing behaviour are measured on the finished board, not on the raw compound — which is what a building control officer will ask for.
The rubber foam insulation board is made on a continuous extrusion and foaming line and skived to 25 mm with ±1 mm tolerance. Incoming compound is checked for density and cell structure, and a retained sample from each batch is stored for two years so that any fire or thermal question can be traced to its production record.
Myreal Energy Saving (Shanghai) Co., Ltd has supplied fire-retardant rubber foam insulation board to contractors in Europe, the Middle East and Southeast Asia since 2009, including plant rooms, metro stations and hospital projects where documentation has to be complete before handover.
| Parameter | Specification |
|---|---|
| Product | MYREAL Flexible Rubber Foam Board for Refrigeration Equipment Insulation |
| Model | FR-25100/ST |
| Thickness | 25 mm |
| Nominal Density | 50 kg/m³ |
| Standard Width | 1.0 m (1.5 m optional) |
| Application | Refrigeration equipment insulation |
| Service Temperature | -50 °C to +110 °C |
| Density Range | 40–60 kg/m³ |
| Thermal Conductivity (0 °C) | ≤0.032–0.034 W/(m·K) |
| Fire Retardant | B1 |
| Oxygen Index | ≥32 % |
| Smoke Classification | ≤75 % |
| Water Absorption | ≤10 % |
| Water Vapor Permeability | ≥10,000 g/m²·h |
| Tear Strength | ≥3.5 N/cm |
| Dimensional Stability (105 °C, 7 days) | ≤10 % |
| Compression Recovery (50 %, 72 h) | ≥70 % |
| Noise Reduction | 30–35 dB |
| UV Resistance | No surface cracks in 460 h |
| Ozone Resistance | 202 MPa, 200 h, no cracks |
| Aging Resistance | 150 h, slight colour change, no cracks |
| Chemical Resistance | Stable to building material chemicals |
| Width (m) | Product Code | Thickness (mm) | Area (m²/roll) | Length (m) |
|---|---|---|---|---|
| 1 | FR-06100/ST | 6 | 30 | 30 |
| 1 | FR-10100/ST | 10 | 20 | 20 |
| 1 | FR-13100/ST | 13 | 15 | 15 |
| 1 | FR-15100/ST | 15 | 13 | 13 |
| 1 | FR-20100/ST | 20 | 10 | 10 |
| 1 | FR-25100/ST | 25 | 8 | 8 |
| 1 | FR-30100/ST | 30 | 6 | 6 |
| 1 | FR-35100/ST | 35 | 6 | 6 |
| 1.5 | FR-13150/ST | 13 | 22.5 | 15 |
| 1.5 | FR-15150/ST | 15 | 19.5 | 13 |
| 1.5 | FR-20150/ST | 20 | 15 | 10 |
| 1.5 | FR-25150/ST | 25 | 12 | 8 |
| 1.5 | FR-30150/ST | 30 | 9 | 6 |
| 1.5 | FR-35150/ST | 35 | 9 | 6 |
| 1.5 | FR-40150/ST | 40 | 7.5 | 5 |
| 1.5 | FR-50150/ST | 50 | 6 | 4 |
- B1 (GB 8624) fire performance on the finished rubber foam insulation board, with a test report supplied for each batch.
- Low smoke development and self-extinguishing behaviour suit plant rooms, escape routes and public areas.
- 25 mm thickness delivers a ≤0.034 W/(m·K) thermal break on both cold and hot ductwork.
- Density of 50 kg/m³ gives a firm board that holds its shape on large duct panels and equipment casings.
- Closed-cell structure with a vapor permeability above 10,000 g/m²·h limits condensation and corrosion under insulation.
- Panels are cut to 1 m × 2 m and packed in cartons or PE bags for direct site delivery.
- Plant room and machine room duct insulation
- Public buildings with reaction-to-fire class requirements
- Shopping malls, hospitals and schools
- Kitchen extract and ventilation ductwork
- Refrigeration equipment and cold room panel lining
The board is tested to B1 (GB 8624) on the finished product, with low smoke development and self-extinguishing behaviour. The batch test report is issued with the shipping documents so it can be filed with the project submittal.
For outdoor ductwork the rubber foam insulation board should be protected with a foil facing, a metal jacket or a UV-resistant coating. The fire performance itself is unaffected, but direct sunlight will degrade the exposed elastomeric surface over time.
Fire performance comes from the formulation, not from thickness, so 25 mm and 32 mm share the same B1 rating. Thickness is selected from the thermal and condensation calculation for the duct.
Butt-fit the panels, apply contact adhesive to both faces, allow the adhesive to become tack-free and press together. All joints and corners should be sealed to keep the vapour barrier continuous.