MYREAL High Density Rubber Foam Insulation Board for Thermal Protection
Basic Properties
Trading Properties
| Model Number: | FR-35100/ST | Thickness: | 35mm |
|---|---|---|---|
| Roll Width: | 1.0 M (1.5 M Optional) | Density: | 60 Kg/m3 |
| Thermal Conductivity: | ≤0.032-0.034 W/(m.K) | Fire Rating: | B1 |
| Oxygen Index: | ≥32 % | Service Temperature: | -50 C To +110 C |
| Water Vapor Permeability: | ≥10,000 G/m2-h | Compression Recovery: | ≥70 % |
| Noise Reduction: | 30-35 DB | Dimensional Stability: | ≤10 % |
| Application: | Thermal Protection | Product Name: | High Density Rubber Foam Insulation Board |
The MYREAL high density rubber foam insulation board is produced for thermal protection on irregular surfaces, fittings and vessel wrapping. Boards are supplied at 1 m × 2 m in 35 mm thickness at 60 kg/m³, with a thermal conductivity of ≤0.034 W/(m·K).
High density matters on large equipment and vessel work. This rubber foam insulation board holds its shape when wrapped around curved shells and complex fittings, and it maintains a stable thermal break without sagging or thinning at the bends. Elongation above 150% allows the board to follow tight radii without cracking.
Low temperature flexibility is tested at -50 °C with no cracking — the property that decides whether an insulation board survives a cold start on a refrigeration or process line. Boards are skived to 35 mm within ±1 mm, and a retained sample from each batch is kept for two years.
Myreal Energy Saving (Shanghai) Co., Ltd has supplied high density rubber foam insulation board to industrial contractors in Europe, the Middle East and Southeast Asia since 2009, mainly for refrigeration, process cooling and vessel insulation packages.
| Parameter | Specification |
|---|---|
| Product | MYREAL High Density Rubber Foam Insulation Board for Thermal Protection |
| Model | FR-35100/ST |
| Thickness | 35 mm |
| Nominal Density | 60 kg/m³ |
| Standard Width | 1.0 m (1.5 m optional) |
| Application | Thermal protection |
| Service Temperature | -50 °C to +110 °C |
| Density Range | 40–60 kg/m³ |
| Thermal Conductivity (0 °C) | ≤0.032–0.034 W/(m·K) |
| Fire Retardant | B1 |
| Oxygen Index | ≥32% |
| Smoke Classification | ≤75% |
| Water Absorption | ≤10% |
| Water Vapor Permeability | ≥10,000 g/m²·h |
| Tear Strength | ≥3.5 N/cm |
| Dimensional Stability (105 °C, 7 days) | ≤10% |
| Compression Recovery (50%, 72 h) | ≥70% |
| Noise Reduction | 30–35 dB |
| UV Resistance | No surface cracks in 460 h |
| Ozone Resistance | 202 MPa, 200 h, no cracks |
| Aging Resistance | 150 h, slight colour change, no cracks |
| Chemical Resistance | Stable to building material chemicals |
| Width (m) | Product Code | Thickness (mm) | Area (m²/roll) | Length (m) |
|---|---|---|---|---|
| 1 | FR-06100/ST | 6 | 30 | 30 |
| 1 | FR-10100/ST | 10 | 20 | 20 |
| 1 | FR-13100/ST | 13 | 15 | 15 |
| 1 | FR-15100/ST | 15 | 13 | 13 |
| 1 | FR-20100/ST | 20 | 10 | 10 |
| 1 | FR-25100/ST | 25 | 8 | 8 |
| 1 | FR-30100/ST | 30 | 6 | 6 |
| 1 | FR-35100/ST | 35 | 6 | 6 |
| 1.5 | FR-13150/ST | 13 | 22.5 | 15 |
| 1.5 | FR-15150/ST | 15 | 19.5 | 13 |
| 1.5 | FR-20150/ST | 20 | 15 | 10 |
| 1.5 | FR-25150/ST | 25 | 12 | 8 |
| 1.5 | FR-30150/ST | 30 | 9 | 6 |
| 1.5 | FR-35150/ST | 35 | 9 | 6 |
| 1.5 | FR-40150/ST | 40 | 7.5 | 5 |
| 1.5 | FR-50150/ST | 50 | 6 | 4 |
- High density board holds its shape on curved shells, vessel heads and irregular fittings without sagging.
- 35 mm thickness provides a deeper thermal break where surface temperature margins are tight.
- Elongation above 150% lets the flexible rubber foam insulation board follow tight radii without cracking.
- Low temperature flexibility is verified at -40 °C, so the board survives cold starts on refrigeration lines.
- Closed cell structure with a vapor permeability above 10,000 g/m²·h limits moisture ingress and corrosion under insulation.
- B1 (GB 8624) fire performance with an oxygen index above 32% is available with batch test reports for the finished rubber foam insulation board.
- Vessel, tank and heat exchanger wrapping
- Irregular fittings, flanges and valve bodies
- Refrigeration and process cooling pipework
- Industrial duct and equipment thermal protection
- Marine and offshore insulation packages
A high density board resists compression and sagging, so the installed thickness stays close to the design thickness. On vessels and irregular fittings, that is what keeps the calculated thermal protection valid over the life of the plant.
Yes. Elongation above 150% and tested flexibility at -40 °C allow the rubber foam insulation board to follow tight radii without cracking. For very small diameters, a thinner sheet is usually easier to wrap cleanly.
It is used on chilled and low temperature service down to -40 °C. For sub-zero duty we check the condensation and ice formation risk and may recommend a vapour barrier jacket over the board.
Apply contact adhesive to both the board and the vessel surface, allow both to become tack free, press firmly and seal all joints. On vertical surfaces, banding or stud fixing can be added for extra security.