logo

MYREAL Class 1 Rubber Foam Insulation Sheet for HVAC Ductwork

Basic Properties

Place of Origin:Shanghai, China
Brand Name:MYREAL
Certification:ISO 9001:2015, CE
Model Number:FR-06100/ST

Trading Properties

Minimum Order Quantity:1 carton
Standard Packaging:Cartons / PE Bags
Delivery Time:15-20 days
Payment Terms:T/T
Supply Ability:Subject to order quantity and specifications
Specifications
Model Number: FR-06100/ST Thickness: 6mm
Roll Width: 1.0 M (1.5 M Optional) Density: 40 Kg/m3
Thermal Conductivity: ≤0.032-0.034 W/(m.K) Fire Rating: B1
Oxygen Index: ≥32 % Service Temperature: -50 C To +110 C
Water Vapor Permeability: ≥10,000 G/m2-h Compression Recovery: ≥70 %
Noise Reduction: 30-35 DB Dimensional Stability: ≤10 %
Application: HVAC Ductwork Product Name: Class 1 Rubber Foam Insulation Sheet
Product Description
Product Overview

The MYREAL Class 1 rubber foam insulation sheet is a 6mm closed-cell elastomeric sheet with an acrylic pressure-sensitive adhesive and a peel-back liner, engineered for HVAC ductwork where site time is short. It is supplied at 40 kg/m³ with a thermal conductivity of ≤0.034 W/(m·K).

The adhesive is the difference. A factory-applied acrylic layer removes the separate glue stage, so the self-adhesive rubber foam insulation sheet goes straight onto cleaned duct or equipment surfaces. The peel-back liner protects the adhesive until the moment of installation, and the bond reaches handling strength within minutes.

Every roll and sheet is produced on a continuous extrusion and foaming line, laminated with adhesive and skived to 6mm within ±1 mm. Incoming compound is tested for density and cell structure, and a retained sample from each batch is kept for two years so adhesive or thermal questions can be traced back.

Myreal Energy Saving (Shanghai) Co., Ltd has supplied self-adhesive rubber foam insulation sheet to HVAC and refrigeration contractors in Europe, the Middle East and Southeast Asia since 2009, mostly for retrofit work in occupied buildings where fast, clean installation matters.

Technical Specifications
Parameter Specification
ProductMYREAL Class 1 Rubber Foam Insulation Sheet for HVAC Ductwork
ModelFR-06100/ST
Thickness6mm
Nominal Density40 kg/m³
Standard Width1.0 m (1.5 m optional)
ApplicationHVAC ductwork
Service Temperature-50 °C to +110 °C
Density Range40–60 kg/m³
Thermal Conductivity (0 °C)≤0.032–0.034 W/(m·K)
Fire RetardantB1
Oxygen Index≥32 %
Smoke Classification≤75 %
Water Absorption≤10 %
Water Vapor Permeability≥10,000 g/m²·h
Tear Strength≥3.5 N/cm
Dimensional Stability (105 °C, 7 days)≤10 %
Compression Recovery (50 %, 72 h)≥70 %
Noise Reduction30–35 dB
UV ResistanceNo surface cracks in 460 h
Ozone Resistance202 MPa, 200 h, no cracks
Aging Resistance150 h, slight colour change, no cracks
Chemical ResistanceStable to building material chemicals
Standard Roll Sizes
Width (m) Product Code Thickness (mm) Area (m²/roll) Length (m)
1FR-06100/ST63030
1FR-10100/ST102020
1FR-13100/ST131515
1FR-15100/ST151313
1FR-20100/ST201010
1FR-25100/ST2588
1FR-30100/ST3066
1FR-35100/ST3566
1.5FR-13150/ST1322.515
1.5FR-15150/ST1519.513
1.5FR-20150/ST201510
1.5FR-25150/ST25128
1.5FR-30150/ST3096
1.5FR-35150/ST3596
1.5FR-40150/ST407.55
1.5FR-50150/ST5064
Key Advantages
  • Factory-applied acrylic adhesive turns the self-adhesive rubber foam insulation sheet into a one-step installation.
  • Peel-back liner keeps the adhesive clean until the sheet is positioned, so there is no dust or waste on site.
  • 6mm thickness fits inside tight ceiling voids and equipment casings during retrofit work.
  • Closed-cell structure with a vapor permeability above 10,000 g/m²·h keeps condensation out of the insulation.
  • B1 (GB 8624) fire performance suits occupied buildings and public areas.
  • Density of 40 kg/m³ stays consistent across the sheet for repeatable thermal performance.
Typical Applications
  • HVAC duct wrapping in retrofit projects
  • Fan coil and air handling unit casing lining
  • Chilled water pipe wrap in tight spaces
  • Vessel and equipment surface insulation
  • Acoustic and thermal lining of duct plenums
Frequently Asked Questions
How strong is the adhesive on the self-adhesive rubber foam insulation sheet?

The acrylic pressure-sensitive layer is applied in line and protected by a peel-back liner. On a clean, dry, dust-free surface it reaches handling strength within minutes, and full bond strength develops over 24 hours.

What surface preparation is needed before applying the sheet?

The surface must be clean, dry and free of oil, dust and release agents. Wipe metal duct with a suitable cleaner, let it dry, then peel the liner back progressively and press the rubber foam insulation sheet down with a roller.

Is 6mm thick enough for duct insulation?

6mm is normally used where space is limited or where the duct is inside a conditioned space and only a light thermal break is required. For cold ducts in humid areas we recommend 13mm or 20mm and provide a condensation calculation.

Can the adhesive version be used outdoors?

For outdoor use, protect the self-adhesive rubber foam insulation sheet with a foil facing, a metal jacket or a UV-resistant coating. The adhesive itself is intended for indoor and protected outdoor service.