logo

Industrial Building Insulation Phenolic Board 75 mm For Wall Roof Envelope

Basic Properties

Place of Origin:China
Brand Name:MYREAL
Certification:ISO、SGS、CE
Model Number:PF-I75

Trading Properties

Minimum Order Quantity:1 carton
Standard Packaging:Cartons / PE Bags
Delivery Time:2-3weeks
Payment Terms:T/T
Supply Ability:Subject to order quantity and specifications
Specifications
Product Name: Industrial Building Insulation Phenolic Board Product Type: Foil Faced Phenolic Building Board
Core Material: Rigid Phenolic Foam, Closed Cell, CFC Free Density: 40 - 55 Kg/m3
Thermal Conductivity: <= 0.032 W/(m.K) At 10 C Mean Temperature Compressive Strength: >= 0.10 MPa (100 KPa)
Dimensional Stability: <= 2.0% After 7 D At -40 / 70 / 130 C Oxygen Index: >= 38%
Smoke Density Ratio: <= 10 Service Temperature: -40 To 130 C
Thickness: 75 Mm Application: Industrial Building Wall And Roof Envelope Insulation
Thermalconductivity: 0.018-0.025 W/m·K Materialtype: Phenolic Resin
Applicationareas: Building Insulation, HVAC, Refrigeration Usage: Construction
Chemicalresistance: Resistant To Acids And Alkalis Type: Rock Wool
Acousticinsulation: Good Sound Absorption Properties Closedcellcontent: >90%
Shape: Sheet Formfactor: Panels, Blocks, Or Spray-applied
Productname: Phenolic Foam Fireresistance: Class A1 (non-combustible)
Thermal Conductivity: 0.041 W/mK Design Style: Modern
Compressivestrength: 0.2-0.5 MPa
Product Description

Industrial Building Insulation Phenolic Board 75 mm for Wall Roof Envelope

Industrial buildings combine large spans, high internal temperatures and long service life, and the insulation has to survive all three. This 75 mm phenolic board is specified where a factory, warehouse or process building needs a thin, high performance envelope that will not slump between purlins over twenty years.

The foam is closed cell with 0.032 W/(m.K) conductivity and a service range from minus 40 to 130 degrees. That range covers unheated warehouses in winter and plant rooms above process equipment in summer without dimensional change beyond two percent, so the industrial building insulation layer stays continuous.

Boards are foil faced for vapour control and are fixed to the envelope with mechanical fasteners or bonded into a sandwich panel. Joints are staggered and taped, and penetrations are sealed, because industrial building insulation performance is decided at the details rather than in the middle of the sheet.

Large industrial projects usually take the board in phased deliveries matched to the cladding programme, and each industrial building insulation delivery is checked against the panel schedule on arrival.

Each industrial building insulation package is delivered against the cladding programme, and the industrial building insulation is checked on arrival against the panel schedule. Where a factory runs hot process equipment the industrial building insulation is specified with a foil facing that reflects radiant heat.

Key Advantages

  • Service range minus 40 to 130 C suits process and warehouse buildings
  • Conductivity 0.032 W/(m.K) keeps envelope thickness down
  • Dimensional stability within 2.0% over the full temperature range
  • Foil facing provides vapour control and a clean surface
  • Rigid board spans between purlins without slumping
  • Suits both sandwich panel cores and site applied lining

Technical Specifications

product nameIndustrial Building Insulation Phenolic Board
Product TypeFoil faced phenolic building board
Core MaterialRigid phenolic foam, closed cell, CFC free
Density40 - 55 kg/m3
Thermal Conductivity<= 0.032 W/(m.K) at 10 C mean temperature
Compressive Strength>= 0.10 MPa (100 kPa)
Dimensional Stability<= 2.0% after 7 d at -40 / 70 / 130 C
Oxygen Index>= 38%
Smoke Density Ratio<= 10
Service Temperature-40 to 130 C
Thickness75 mm
ApplicationIndustrial building wall and roof envelope insulation

Typical Applications

  • Factory and warehouse envelopes
  • Process buildings and plant rooms
  • Cold storage and food factories
  • Logistics and distribution centres
  • Workshop wall and roof linings
  • Industrial refurbishment projects

Frequently Asked Questions

Q: Can it be used in a sandwich panel?

A: Yes, either as a loose core for your line or as a finished panel from our lamination line.

Q: What fixing is used on site?

A: Mechanical fasteners at the purlin or stud line, with adhesive where the system allows, and joints taped.

Q: How does it perform in a cold store?

A: It is used up to moderate cold store duty, and for deep freeze work a thicker board or a different facing should be assessed.

Q: Do you provide U value calculations?

A: Yes, send wall and roof build ups and we return the calculation with the recommended thickness.

MYREAL produces industrial building phenolic insulation boards on a continuous lamination line in Shanghai and supplies projects in Europe, the Middle East and Southeast Asia. Contact our technical team for datasheets, samples and test reports.

Contact Details
Myreal Energy Saving (Shanghai) Co., Ltd.

Contact Person: Mrs. Betsy Ouyang

Tel: +86 17740800950

Send your inquiry directly to us
(0/3000)