logo

Lightweight Ceramic Stone Cladding Panel 35mm 8.8kg Per Square Meter Replacing 30mm Granite Slab

Basic Properties

Place of Origin:China
Brand Name:MYREAL
Certification:ISO 9001, CE, SGS
Model Number:MY-03-900*600

Trading Properties

Minimum Order Quantity:2000m²
Price:35-40USD
Standard Packaging:Pallet
Delivery Time:2-3 weeks after deposit and sample approval
Payment Terms:T/T,L/C at sight
Supply Ability:20,000 Square Meters per Month
Specifications
Product Name: Lightweight Ceramic Stone Cladding Panel That Replaces A 30 Mm Granite Slab Application: Facade Cladding On Buildings With A Structural Load Cap Or A Thin Existing Frame
HS Code: 6914100000 Areal Weight (35 Mm): About 8.8 Kg/m2 At Nominal 250 Kg/m3
Comparison: 30 Mm Granite Slab: 70-80 Kg/m2 Standard Thickness: 35 Mm (30, 40, 45, 50 Mm On Request)
Material: Foamed Ceramic, Perlite Tailings Based Inorganic Body Maximum Working Temperature: 1200 DegC
Non-combustibility: Class A1 Non-combustible Thermal Conductivity (100 DegC): 0.064 W/(m.K)
Heat Storage Coefficient: 1.5 W/(m2.K) Volumetric Water Absorption: 0.6%
Density: 180-330 Kg/m3 Compressive Strength: 0.40-2.00 MPa
Tensile Strength: 0.15-0.26 MPa Flexural Strength: >=0.60 MPa
Freeze-Thaw Resistance: Glaze Without Cracks And Flaking Pollution Resistance: Class 3
Chemical Resistance: Class GLA Standard Sizes: 900 X 600 / 1200 X 600 / 1200 X 900 Mm
Product Description

Lightweight Ceramic Stone Cladding Panel that Replaces a 30 mm Granite Slab

In short: The FJ-1002H is a 35 mm lightweight ceramic stone cladding panel at about 8.8 kg/m2, replacing a 30 mm granite slab of 70-80 kg/m2, Class A1 non-combustible to GB 8624 and 0.6% water absorption.

Weight is the hidden cost of a stone facade. A 30 mm granite slab runs 70–80 kg/m², which drives anchor size, keel section, slab handling and, on retrofit work, structural strengthening. This lightweight ceramic stone cladding panel weighs about 8.8 kg/m² at 35 mm — roughly one eighth of the stone it replaces.

The saving is structural, not cosmetic. Lighter panels mean smaller back-groove anchors, lighter horizontal rails, fewer crane lifts and faster installation per square metre. On existing buildings the same reduction often decides whether a stone look overclad is feasible at all without strengthening the frame.

Core Advantages

  • About 8.8 kg/m² at 35 mm: against 70–80 kg/m² for a 30 mm granite slab, so anchor count, keel steel and lifting plant all come down
  • Full Stone Look: fired-in mineral grain reproduces granite colour and speckle without the weight, joints and slab-matching problems of natural stone
  • Class A1 Non-Combustible: inorganic body rated Class A1 to GB 8624, suitable for facade and compartment lining use
  • 0.6% Water Absorption: closed cells and a sintered skin resist rain, frost and pollution without sealing maintenance
  • Cuts Like Stone on Site: standard stone tooling cuts, grooves and drills the panel, so window returns and corners are handled by the fixing crew
  • Fewer Fixing Risks: each panel can be carried and set by two installers, removing the vacuum-lifter dependency that slows stone crews

Technical Data

Property Value Standard
Areal Weight (35 mm) About 8.8 kg/m² at nominal 250 kg/m³ Batch weighing
Comparison 30 mm granite slab: 70–80 kg/m² Reference data
Standard Thickness 35 mm (30, 40, 45, 50 mm on request) Factory standard
Application Exterior facade and column cladding Project drawing
Material Foamed ceramic, perlite tailings based inorganic body Batch test report
Maximum Working Temperature 1200°C Factory standard
Non-combustibility Class A1 non-combustible GB 8624
Thermal Conductivity (100°C) 0.064 W/(m·K) GB/T 10295
Heat Storage Coefficient 1.5 W/(m²·K) JG/T 511
Volumetric Water Absorption 0.6% Supplied specification
Density 180–330 kg/m³ GB/T 5486
Compressive Strength 0.40–2.00 MPa GB/T 5486
Tensile Strength 0.15–0.26 MPa GB/T 5486
Flexural Strength ≥0.60 MPa GB/T 5486
Freeze-Thaw Resistance Glaze without cracks and flaking GB/T 5486
Pollution Resistance Class 3 JG/T 511
Chemical Resistance Class GLA JG/T 511
Standard Sizes 900 × 600 / 1200 × 600 / 1200 × 900 mm Factory tolerance ±1 mm
HS Code 6914100000 Customs classification

Application

  • Facade cladding on buildings with a structural load cap or a thin existing frame
  • Column and beam cladding where stone weight would need extra steel
  • High-rise elevations where crane time and slab handling dominate the programme
  • Canopies, soffits and balcony fascias that cannot take a stone skin
  • Stone look elevations on steel-frame industrial and logistics buildings
  • Interior atria and shopping mall columns where panel handling is manual

Installation & Fixing

Above 10 m use a ventilated dry-hanging system with aluminium or zinc-coated steel keel, stainless back-groove anchors and a 15–20 mm open joint, packed with PE backer rod and silicone sealant. Below 10 m an adhesive-plus-anchor method is acceptable when the substrate is flat and wind load has been verified. Because the panel is light, two-person handling with a suction cup is practical; send facade area and storey height and we will return a load calculation and fixing layout.

Packing

Supplied on pallets, export packing about 621 kg gross per crate at 110 × 92 × 200 cm, loaded into 20ft or 40ft containers with fumigation-free packing. Store under cover, keep pallets level and avoid point loads on the decorated face.

FAQ

Q: How much weight does the panel really save?

A: About 61–71 kg per square metre against a 30 mm granite slab, which on a 3000 m² elevation is roughly 180–210 tons of dead load removed from the structure.

Q: Is the panel strong enough for a high-rise facade?

A: Yes. Compressive strength is 0.40–2.00 MPa, tensile 0.15–0.26 MPa and flexural strength ≥0.60 MPa to GB/T 5486, and the dry-hanging system carries wind load through stainless anchors; we supply the calculation with the shop drawings.

Q: What are the MOQ and lead time?

A: MOQ is 2000 m² per order and lead time is 2–3 weeks after deposit and sample approval; phased sites can be shipped in partial lots.

Q: How do you control quality before shipment?

A: Each batch is tested to GB/T 5486, GB 8624 and GB/T 10295, compared with the approved colour sample under daylight, and photographed pallet by pallet before loading.

Send your facade area, storey height and existing structure type, and we will return a weight comparison, fixing layout and quotation within two working days.

Key Facts

PropertyValue
MaterialSintered inorganic ceramic body
Thickness35 mm (30/40/45/50 mm on request)
Areal weightabout 8.8 kg/m2, vs 70-80 kg/m2 for 30 mm granite
Panel size900 x 600, 1200 x 600, 1200 x 900 mm
Fire ratingClass A1 non-combustible, GB 8624
Water absorption0.6%
Compressive strength0.40-2.00 MPa, GB/T 5486
Tensile strength0.15-0.26 MPa, GB/T 5486
Flexural strength>=0.60 MPa, GB/T 5486
Order termsMOQ 2000 m2, USD 35-40/m2, 2-3 weeks

Quick Answers

Q: How much lighter is it than granite?

A: About 8.8 kg/m2 at 35 mm against 70-80 kg/m2 for a 30 mm granite slab, a saving of roughly 61-71 kg per square metre.

Q: Why does the weight matter?

A: Lighter panels mean smaller anchors, lighter rails, fewer crane lifts and, on retrofit work, often no structural strengthening.

Q: Is a light panel still strong enough?

A: Compressive strength is 0.40-2.00 MPa, tensile 0.15-0.26 MPa and flexural >=0.60 MPa to GB/T 5486, with wind load carried by stainless anchors.

Q: Can it be cut on site?

A: Yes, with standard stone tooling for window returns, corners and openings.

Q: What are the order terms?

A: MOQ 2000 m2, USD 35-40 per m2, 2-3 weeks after deposit and sample approval.

Contact Details
Myreal Energy Saving (Shanghai) Co., Ltd.

Contact Person: Mrs. Betsy Ouyang

Tel: +86 177 4080 0950

Send your inquiry directly to us
(0/3000)