Ready to Fix Ceramic Wall Unit Prefab Facade Panel with 50mm Panel and Class A1 Non-Combustible Insulated Cladding Module
Basic Properties
Trading Properties
| Product Name: | Modular Granite Look Ceramic Wall Unit Delivered Ready To Fix | Application: | Prefabricated And Modular Buildings Where The Envelope Is Closed By Unit |
|---|---|---|---|
| HS Code: | 6914100000 | Assembly: | Panel Bonded To Insulation With Factory-fitted Brackets |
| Standard Thickness: | 50 Mm Panel In A 90-130 Mm Unit Depth | Module Size: | Up To 1200 X 900 Mm, Subject To Handling And Transport |
| Areal Weight (50 Mm): | About 12.5 Kg/m2 At Nominal 250 Kg/m3 | Surface Pattern: | Granite Look, Honed Or Profiled |
| Material: | Foamed Ceramic, Perlite Tailings Based Inorganic Body | Maximum Working Temperature: | 1200 DegC |
| Non-combustibility: | Class A1 Non-combustible | Thermal Conductivity (100 DegC): | 0.064 W/(m.K) |
| Heat Storage Coefficient: | 1.5 W/(m2.K) | Volumetric Water Absorption: | 0.6% |
| Density: | 180-330 Kg/m3 | Compressive Strength: | 0.40-2.00 MPa |
| Tensile Strength: | 0.15-0.26 MPa | Flexural Strength: | >=0.60 MPa |
| Freeze-Thaw Resistance: | Glaze Without Cracks And Flaking | Pollution Resistance: | Class 3 |
| Chemical Resistance: | Class GLA | Standard Sizes: | 900 X 600 / 1200 X 600 / 1200 X 900 Mm |
In short: The FJ-1110QS is a 50 mm prefabricated granite look ceramic facade unit assembled in the factory with insulation and fixing brackets, Class A1 non-combustible to GB 8624 and 0.6% water absorption, delivered ready to fix.
Site time is the expensive part of a facade, and it is the part most exposed to weather. This modular granite look ceramic wall unit moves that work off site: the 50 mm ceramic panel is assembled in the factory with its insulation and fixing brackets in place, so the elevation closes by module instead of by trade.
Factory assembly also resolves the quality questions before the crane arrives — joint width, bracket position, colour match and insulation continuity are all set on a bench rather than 40 m up. Because every component is inorganic and the panel is Class A1 non-combustible, the finished unit does not introduce a combustible layer into the envelope.
- Ready-to-Fix Modules: Panel, insulation and brackets arrive as one unit, so site work reduces to setting and sealing.
- Factory-Controlled Quality: Joint width, bracket position and colour match are set on the bench, not on the scaffold.
- 50 mm Panel Section: A stiff outer skin at ≥0.60 MPa flexural strength holds its plane across the module without a backing board.
- Insulation Built In: Continuous insulation within the unit removes the gaps that site-laid insulation leaves at brackets.
- Class A1 Non-Combustible: Panel and insulation are inorganic, so the unit does not feed a cavity fire.
- Programme Certainty: Modules can be produced while groundworks finish, which shortens the critical path on tight sites.
| Property | Value | Standard |
|---|---|---|
| Assembly | Panel bonded to insulation with factory-fitted brackets | Approved shop drawing |
| Standard Thickness | 50 mm panel in a 90–130 mm unit depth | Factory standard |
| Module Size | Up to 1200 * 900 mm, subject to handling and transport | Factory limit |
| Areal Weight (50 mm) | About 12.5 kg/m² at nominal 250 kg/m³ | Batch weighing |
| Surface Pattern | Granite look, honed or profiled | Sample approval |
| Application | Prefabricated facade and modular building envelopes | Project drawing |
| Material | Foamed ceramic, perlite tailings based inorganic body | Batch test report |
| Maximum Working Temperature | 1200°C | Factory standard |
| Non-combustibility | Class A1 non-combustible | GB 8624 |
| Thermal Conductivity (100°C) | 0.064 W/(m·K) | GB/T 10295 |
| Heat Storage Coefficient | 1.5 W/(m²·K) | JG/T 511 |
| Volumetric Water Absorption | 0.6% | Supplied specification |
| Density | 180–330 kg/m³ | GB/T 5486 |
| Compressive Strength | 0.40–2.00 MPa | GB/T 5486 |
| Tensile Strength | 0.15–0.26 MPa | GB/T 5486 |
| Flexural Strength | ≥0.60 MPa | GB/T 5486 |
| Freeze-Thaw Resistance | Glaze without cracks and flaking | GB/T 5486 |
| Pollution Resistance | Class 3 | JG/T 511 |
| Chemical Resistance | Class GLA | JG/T 511 |
| Standard Sizes | 900 * 600 / 1200 * 600 / 1200 * 900 mm | Factory tolerance ±1 mm |
| HS Code | 6914100000 | Customs classification |
- Prefabricated and modular buildings where the envelope is closed by unit.
- Projects with a short construction window and a fixed handover date.
- High-rise elevations where scaffolding time must be minimised.
- Cold-store and plant enclosure walls needing a continuous insulated skin.
- Repeat residential typologies where modules can be standardised.
- Remote sites with limited local labour and weather windows.
Units are lifted by their designated lifting points only and set to the setting-out plan, starting from a levelled base rail and working to the corner. Align brackets to the structure, check plumb and joint width per module, then seal the joints with a fire-rated sealant and keep the cavity drained at the base.
Do not modify brackets on site without approval, since the unit wind-load design depends on their position. Send your module grid, wall build-up and U-value target and we will return a unit shop drawing and lifting plan.
Units ship on purpose-built stillages with brackets protected and modules separated by foam blocks — normally 4–6 units per stillage and about 621 kg gross per crate, loaded by module number against the setting-out plan.
A: 2000 m² of envelope, since a module line has to be set up and a shop drawing approved before production; standardised typologies make repeat orders easier.
A: Yes, provided we receive the frame survey and bracket zones; the bracket layout is designed to your grid and the unit is produced to match.
A: MOQ is 2000 m² per order and lead time is 2–3 weeks after deposit and sample approval; phased sites can be shipped in partial lots.
A: Each batch is tested to GB/T 5486, GB 8624 and GB/T 10295, compared with the approved colour sample under daylight, and photographed pallet by pallet before loading.
Send your module grid, wall build-up and programme dates, and we will return a unit shop drawing, lifting plan and quotation within three working days.
Key Facts
| Property | Value |
|---|---|
| Material | Sintered inorganic ceramic panel in a factory assembly |
| Thickness | 50 mm panel in a 90-130 mm unit depth |
| Areal weight | about 12.5 kg/m2 for the ceramic skin |
| Module size | up to 1200 x 900 mm |
| Assembly | panel, insulation and brackets bonded in factory |
| Fire rating | Class A1 non-combustible, GB 8624 |
| Water absorption | 0.6% |
| Flexural strength | >=0.60 MPa, GB/T 5486 |
| HS code | 6914100000 |
| Order terms | MOQ 2000 m2, USD 35-40/m2, 3-4 weeks |
Quick Answers
A: A finished unit: ceramic panel, insulation and fixing brackets bonded on the factory line, with a lifting and setting-out plan.
A: Joint width, bracket position and colour match are set on a bench instead of on a scaffold, and the envelope closes by module.
A: The panel is Class A1 to GB 8624 and the insulation is inorganic, so the unit adds no combustible layer.
A: Yes, from your frame survey and bracket zones the layout is designed to your grid.
A: MOQ 2000 m2, USD 35-40 per m2, 3-4 weeks including shop drawing approval.
Contact Person: Mrs. Betsy Ouyang
Tel: +86 177 4080 0950